Recommended Plan
Eight builds. Every deployment size.
Pre-engineered configurations from an 8-rack edge row to a 36-rack AI cluster — each one a validated combination of Total Electronics compute, networking, cooling, and monitoring. Find your size, then inquire.
Plan 1 — Edge Compute Row
R8 | IL-C8-3K- IT racks8 racks @ 3kW each
- Compute16× Forge X9 CPU nodes
- Network fabric25GbE leaf, dual uplinks
- Cooling2× RackCool 10kW in-row units
- Power distribution40kW PDU set (protection specced per project)
- Footprint3.6m × 3.6m module
- Total cabinets8
Plan 2 — Branch Consolidation
R12 | IL-C12-3K- IT racks12 racks @ 3kW each
- Compute24× Forge X9 CPU nodes
- Network fabric25/100GbE leaf-spine
- Cooling2× RackCool 20kW row packages
- Power distribution60kW PDU set
- Footprint3.6m × 4.8m module
- Total cabinets12
Plan 3 — Enterprise Core
R16 | IL-C16-3K- IT racks16 racks @ 3kW each
- Compute32× Forge X9 CPU nodes
- Network fabric100GbE leaf-spine
- Cooling3× RackCool 20kW row-split systems
- Power distribution80kW PDU set
- Footprint4.8m × 6.0m module
- Total cabinets16
Plan 4 — Mixed Workload Hall
R20 | IL-M20-5K- IT racks20 racks @ 5kW each
- Compute40× Forge X9 nodes, mixed CPU/accelerator
- Network fabric100GbE non-blocking leaf-spine
- Cooling4× RackCool 30kW units
- Power distribution120kW PDU set + wiring cabinet
- Footprint6.0m × 7.2m module
- Total cabinets20 + wiring cabinet
Plan 5 — Regional Hub
R24 | IL-M24-5K- IT racks24 racks @ 5kW each
- Compute48× Forge X9 nodes, mixed CPU/accelerator
- Network fabric100/400G leaf-spine
- Cooling5× RackCool 30kW units
- Power distribution140kW PDU set + mains distribution cabinet
- Footprint6.0m × 8.4m module
- Total cabinets24 + mains cabinet
Plan 6 — Dense Enterprise Hall
R28 | IL-M28-5K- IT racks28 racks @ 5kW each
- Compute56× Forge X9 nodes, mixed CPU/accelerator
- Network fabric400G spine, 100G leaf
- Cooling6× RackCool 30kW + ThermaGate doors on dense rows
- Power distribution160kW PDU set + mains distribution cabinet
- Footprint7.2m × 8.4m module
- Total cabinets28 + mains cabinet
Plan 7 — AI Training Pod
R32 | IL-G32-10K- IT racks32 racks @ 10kW each (GPU rows)
- Compute16× Forge X9 GPU nodes (8× H200-class each) + CPU support
- Network fabric400G non-blocking, RoCEv2 collective-optimized
- CoolingThermaGate 30kW rear doors on every GPU rack
- Power distribution340kW PDU/busway set + mains cabinet
- Footprint8.4m × 9.6m module
- Total cabinets32 + mains & wiring cabinets
Plan 8 — AI Cluster Flagship
R36 | IL-G36-10K- IT racks36 racks @ 10kW each
- Compute24× Forge X9 GPU nodes + storage and CPU rows
- Network fabric400G non-blocking spine-leaf, 800G-ready optics
- CoolingFull liquid: ThermaGate doors + direct-to-chip loops
- Power distribution380kW busway set + mains & wiring cabinets
- Footprint9.6m × 10.8m module
- Total cabinets36 + mains & wiring cabinets
Request a Plan
Tell us which build — we'll price it for your site.
A Total Electronics engineer reviews every plan request against your site conditions, power availability, and workload before quoting.
Ready to choose your plan?
Talk to our engineers to match the right configuration to your capacity requirements and site conditions.